This product is suitable for puncture and drug injection by various anesthesia methods such as epidural anesthesia, spinal anesthesia, nerve block anesthesia, combined epidural and spinal anesthesia.
If you need customized products, Contact Us
This product is suitable for puncture and drug injection by various anesthesia methods such as epidural anesthesia, spinal anesthesia, nerve block anesthesia, combined epidural and spinal anesthesia.
Scale + vernier for depth accuracy (±0.5mm).
Oxidation-resistant needle base.
| TYPE
| PRODUCT
| O.D | LENGTH
| |
| MM | GAUGE | |||
| AN-SII | Atraumatic Spinal Needle | 0.45-0.7 | 26G-22G | 80-150 |
| AN-S | Disposable Spinal Needle | 0.45-0.7 | 26G-22G | 50-150 |
| AN-E | Disposable Epidural Needle | 1.2-1.8 | 18G-15G | 65-150 |
| AN-N | Disposable Nerve-block Needle | 0.5-0.9 | 25G-20G | 80-100 |
This disposable non-traumatic pencil-point spinal needle is designed for precise, single-use spinal anesthesia and lumbar puncture procedures. The pencil-point tip separates rather than cuts dural fibers, significantly reducing the risk of post-dural puncture headache (PDPH) compared to standard cutting-bevel needles. For you, this means improved patient comfort, faster recovery times, and fewer complications during routine spinal blocks or diagnostic taps. Why choose this? It combines a smooth, atraumatic design with a sterile, ready-to-use format, eliminating cross-contamination risks and saving valuable preparation time in the operating room or clinic.
“I have been using these pencil-point needles for about six months in our outpatient spine clinic. Honestly, the patient feedback on post-procedure headaches has dropped noticeably. The 22G gauge provides just the right balance of flow rate for CSF collection and minimal tissue trauma. Look, the packaging is straightforward, and I have not had a single hub detachment issue. The only minor critique is that the stylet can feel a bit stiff on initial insertion, but it does not affect performance.”
— Dr. Michael Torres, D.O., Anesthesiology Specialist, Midwest Surgical Center
| Specification | Detail |
|---|---|
| Needle Type | Pencil-point (Whitacre), non-traumatic |
| Gauge | 22G |
| Length | 3.5 inches (88.9 mm) |
| Tip Design | Closed, blunt pencil-point with lateral opening |
| Hub Connection | Color-coded Luer lock |
| Sterilization | Ethylene oxide (EO) sterile, single-use only |
| Certifications | ISO 134852016 (Certificate No.132299) |
| Quantity per box | 10 individually sealed needles |
| Parameter | Pencil-Point Needle (This Product) | Standard Quincke Cutting Needle |
|---|---|---|
| Tip Shape | Blunt, conical pencil-point | Sharp, beveled cutting edge |
| Dural Fiber Damage | Separation (fibers spread) | Cutting (fibers severed) |
| PDPH Incidence | Low (approx 1-3 percent) | Higher (up to 10-15 percent) |
| Insertion Feel | Requires slightly more pressure | Sharper, quicker entry |
| Flow Rate (22G) | Good for CSF collection and injection | Slightly faster due to cutting tip |
Yes We are a professional manufacturer and exporter of medical devices and consumables with mutiple manufacturing sites in China.
The warranty period is 2-5 years, depending on the product type.
A pencil-point needle has a blunt, rounded tip with a side hole, designed to separate tissue fibers. A standard Quincke needle has a sharp, beveled tip that cuts fibers. The pencil-point design reduces the risk of post-dural puncture headache (PDPH) because the dural hole is smaller and closes more easily.
Yes. The 22G gauge and 3.5 inch length are suitable for both CSF collection (diagnostic) and injection of anesthetic agents (spinal block). The pencil-point tip minimizes trauma in either use case.
This needle is made from non-ferromagnetic stainless steel and is MRI conditional. It should be removed or confirmed safe by the MRI safety officer before scanning.
Follow standard sharps disposal protocols. Place the used needle directly into a puncture-resistant sharps container immediately after use. Do not recap or bend the needle.